CVIS

Hemodynamic pressure monitoring permits continuous assessment of the status of patients and their response to ongoing therapy, thus providing information essential for more precise diagnoses and prompt correction of a problem.

Fysicon provides the solution of a single access point for all patient information. It will help to improve the clinical and financial performance of the department. It supports among other things heart and peripheral catheterization procedures at diagnostics and treatment. CVIS make a complete prerecording of the procedure and provides al the reports that are necessary.

EVOCS voor web 2

Application


With the CVIS you are able to manage all your images (DICOM as well as Non-DICOM), Reports, used Material, Medication, Staff, Appointments and Lab values. It’s graphical interface offers a global overview with direct access of patient files, a complete management of the documents (text and images) and clinical follow-up of patients.

CVIS highlights:

  • Access images in real-time, anytime and anywhere. Images can be accessed inside or outside the hospital or any institution around the world. The multi-modality viewer allows you to view the images in a customized interface per modality
  • Scheduling solution for managing patient and modality resources
  • Webbased PACS integration
  • Departmental inventory management with bar code scanning capability
  • Integration possible with the EPD, HIS or any X-ray vendor, as techniques are based on DICOM & HL 7 protocols
  • The intuitive user interface simplifies tasks
  • Multiple languages available
  • Remote Service

Fully integrated hemodynamic and monitoring system for analysis & calculations. For cardiac & peripheral catheterization procedures:

  • Gradient / Valve / Resistance calculations
  • Thermodilution or Fick for Cardiac Output
  • Complete Full Disclosure
  • Retrospect Pullback Analysis;
  • Integrated Arrhythmia analysis and ST Analysis
  • Intra Cardiac ECG Lead Capability
  • Electro Physiology and ablations
  • FFR
  • The amplifier unit can be mounted horizontal, as well as vertical underneath the X-ray table
  • The central processor unit and the power unit will be installed in the equipment (generator) room

Versatile modules for reporting:

  • Can be linked to major European registries (Cards) and national registries (BCIS, DIPR, CIDR, BWGIC, etc..) through which the data relevant to the cardiac care of patients can be collected and merged
  • Clinical and angiographic follow-up of patients
  • Global and direct overview of the patient file
  • Complete management of the documents
  • (Stress) Ultrasound examinations
  • ECG Management
  • Pacemaker & ICD implants (incl. follow-up)

Specifications

The standard parameters are:

  • 12 Lead ECG (incl. ST en Arrhythmia detection)
  • up to 8 analog outputs for ECG (trigger and wave)
  • 2 IBP Channels
  • IBP
  • NiBP
  • SpO2 (Nellcor)

Optional parameter modules are available for:
Temperature (2 CH), CO, EtCO2 and additional IBP.
The technical specifications of the modules are available upon request.

Specificitions Front-End:

  • Power supply: 20 V
  • Power consumption: < 45 VA
  • Operating Temperature: 10° – 40° C / 50° – 104° F
  • Relative Humidity: < 85 % Non-condensing
  • Safety Class: I, CF
  • Safety requirements: MDD 93/42/EEC, EN 60601-1

Specifications of the Reporting System:

  • Power supply: 90 – 240 V ± 10% 50/60 Hz
  • Power consumption: < 400 VA
  • Safety Class: I
  • Operating Temperature: -10° – +50° C / 14° – 122° F
  • Relative Humidity: < 85 % Non-condensing

Specifications Power Unit:

  • Power supply: 240 V ± 10% 50/60 Hz
  • Power consumption: < 1100 VA
  • Safety Class: II
  • Operating Temperature: 10° – 40° C / 50° – 104° F
  • Relative Humidity: < 85 % Non-condensing